ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

4R70E/4R75E|Page 3360 > < 4R70E/4R75E
Page 2
background image

2. Connect the transmission internal harness to the solenoids.

1. Connect the transmission internal harness connector by pressing it in place by hand and fully seating the connector in place.

2. Connect the EPC solenoid by fully seating the connector in place.

3. Connect the TCC solenoid by fully seating the connector in place.

4. Connect the SSA and SSB by fully seating the connector in place.

5. Connect the TFT sensor.

3. NOTICE: The transmission internal wire harness needs to be properly routed to avoid the potential of damage to the harness. Pinched or

trapped internal wire harness may result in a transmission failure.

Make sure that the internal wire harness is properly routed.

4. Install the manual control lever. For additional information, refer to Manual Control Lever Shaft and Seal  See: Transmission and

Drivetrain/Automatic Transmission/Transaxle/Seals and Gaskets/Service and Repair/4R70E/4R75E/Manual Control Lever Shaft and Seal.

4R70E/4R75E|Page 3360 > < 4R70E/4R75E