5. Disconnect the generator electrical connectors.

6. Position the generator B+ protective cover aside, remove the B+ terminal nut and position the B+ terminal aside.

-

To install, tighten to 17 Nm (150 lb-in).

7. Remove the 4 bolts and the generator bracket.

-

To install, tighten to 10 Nm (89 lb-in).

8. Remove the 2 bolts and the generator.

-

To install, tighten to 25 Nm (18 lb-ft).

9. To install, reverse the removal procedure.