E 450 V8-5.4L (2009)
5. Disconnect the generator electrical connectors.
6. Position the generator B+ protective cover aside, remove the B+ terminal nut and position the B+ terminal aside.
-
To install, tighten to 17 Nm (150 lb-in).
7. Remove the 4 bolts and the generator bracket.
-
To install, tighten to 10 Nm (89 lb-in).
8. Remove the 2 bolts and the generator.
-
To install, tighten to 25 Nm (18 lb-ft).
9. To install, reverse the removal procedure.