E 450 V8-5.4L (2009)
1. Remove the 2 extension housing stud bolts and 4 extension housing bolts.
2. Remove the extension housing and gasket.
Installation
1. Install the extension housing and gasket.
1. Install the extension housing and gasket.
2. Install the 2 extension housing stud bolts and 4 extension housing bolts.
-
Tighten to 55 Nm (41 lb-ft).
2. Install the transmission insulator and retainer and install the bolts.
-
Tighten to 90 Nm (66 lb-ft).
3. Lower the transmission onto the crossmember and tighten the transmission insulator and retainer nuts.
-
Tighten to 90 Nm (66 lb-ft).
4. Connect the catalyst monitoring sensor harness connectors. Install the harness bracket.
5. NOTE: The output shaft and the driveshaft are a balanced assembly.