Page 3
background image

Transmissions without a fixed flange

7. Using the Transmission Extension Housing Seal Remover along with the Torque Converter Fluid Seal Remover and Slide Hammer, remove the

extension housing seal.

Installation

Transmissions without a fixed flange

1. Using the Output Shaft Seal Installer, install the extension housing seal.

Transmissions with a fixed flange

2. Using the Transmission Extension Housing Seal Installer, install the output shaft seal.

3. Using the Output Shaft Locknut Socket, install a new output shaft retaining nut.

-

Tighten to 200 Nm (148 lb-ft).

4. Install the output shaft flange and a new bolt.

-

Tighten to 130 Nm (96 lb-ft).

4R70E/4R75E|Page 3611 > < 4R70E/4R75E|Page 3609