ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Service Precautions|Page 6583
Page 2
background image

5. Disconnect the evaporator outlet fitting. 

-

Discard the O-ring seal.

6. Detach the wire harness.

1

Disconnect the cycling switch electrical connector.

2

Remove the nut and stud and detach the wire harness.

7. Remove the bolts and the suction accumulator.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean mineral oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

2. Evacuate, leak test and charge the refrigerant system.