Econoline E150 1/2 Ton V8-4.6L SOHC VIN W (2001)
Leak Detection Valve: Service and Repair
REMOVAL
1. Remove the evaporative emission canister.
2. Remove the retainer by sliding it off the bracket.
3. Remove the canister vent solenoid.
NOTE:
^
Inspect and install new O-ring seals as necessary.
^
A twisting and pulling motion is necessary to remove the evaporative emission canister vent solenoid.
INSTALLATION
1. To install, reverse the removal procedure.
^
Carry out the evaporative emission system leak test. See: Testing and Inspection/Component Tests and General Diagnostics/Evaporative
Emission System Leak Test
^
Carry out the evaporative emission repair verification drive cycle. See: Testing and Inspection/Component Tests and General
Diagnostics/Evaporative Emission Repair Verification Drive Cycle
NOTE: Lubricate the O-ring seals with MERPOL(R) O-Ring Seal Lubricant or equivalent meeting Ford specification ESE-M99B144-B.