4. Apply maximum vacuum and maintain it for a minimum of three minutes with the engine speed set at idle.
5. Release the vacuum and remove the vacuum pump.
6. CAUTION: Do not overfill the reservoir.
Fill the reservoir.
-
Use Motorcraft MERCON(r) Multi-Purpose ATF XT-2-QDX or MERCON(r) equivalent.
7. Reinstall the vacuum pump. Apply and maintain maximum vacuum.