7. Connect the condenser core refrigerant lines.
1. Lubricate the new O-rings with Motorcraft YN-12c refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B and install the
O-rings.
2. Connect the condenser to evaporator tube.
3. Connect the compressor discharge line.
CAUTION: Use a wrench on each side of the fitting to prevent damage to the A/C fitting.
8. Install the four clamps.
1. Install the clamp.
2. Install the screw.
9. Install the engine air cleaner and the air cleaner outlet tube.
10. Fill the engine cooling system.
11. Reconnect the battery ground cable.
12. Using proper procedures, evacuate and charge the A/C system. See: Service and Repair/Evacuation and Charging
Standard A/C
REMOVAL
1. Using proper procedures, recover the refrigerant.
2. Disconnect the battery ground cable.
3. Remove the engine Air Cleaner (ACL) and the air cleaner outlet tube.
4. Disconnect the condenser core refrigerant lines.
1. Disconnect the compressor discharge line.
2. Disconnect the condenser to evaporator tube.
CAUTION: Use a wrench on each side of the fitting to prevent damage to the A/C fitting.