ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Standard A/C|Page 5687 > < Accumulator HVAC|Specifications|Page 5684
Page 1
background image

Accumulator HVAC: Service and Repair
Standard A/C

REMOVAL

1. Using proper procedures, recover the refrigerant.
2. Remove the battery.

3. Remove the battery tray.

1. Remove the screws.
2. Remove the battery tray.

4. Disconnect the evaporator discharge line.

CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

5. Disconnect the compressor suction line.

1. Remove the screw.
2. Disconnect the compressor suction line.

CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

Standard A/C|Page 5687 > < Accumulator HVAC|Specifications|Page 5684