Econoline E350 1 Ton V8-5.4L Prop SOHC VIN Z (1998)
4. Connect the condenser core refrigerant lines.
1. Lubricate the new O-rings with Motorcraft YN-12c refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B and install the
O-rings.
2. Connect the condenser to evaporator tube.
3. Connect the compressor discharge line.
CAUTION: Use a wrench on each side of the fitting to prevent damage to the A/C fitting.
5. Install the engine air cleaner and the air cleaner outlet tube.
6. Reconnect the battery ground cable.
7. Using proper procedures, evacuate and charge the A/C system. See: Heating and Air Conditioning/Service and Repair/Evacuation and Charging