8. Disconnect the compressor manifold and tube assembly from the condenser and remove the compressor manifold and tube assembly.

^

Discard the O-ring seal.

CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

INSTALLATION

1. To install, reverse the removal procedure.

^

If a new compressor manifold and tube assembly is to be installed, transfer the pressure cutoff switch to the new compressor manifold and tube
assembly.

^

Lubricate the refrigerant system with the correct amount of clean PAG oil.

^

Install new O-ring seals lubricated in clean PAG oil.

2.

Evacuate, leak test, and charge the refrigerant system.