2. Make sure the large RCM connector position assurance lever is in the full release position before attempting to connect the connector.

3. NOTICE: Placing the large Restraints Control Module (RCM) electrical wiring connector into the RCM on an angle, may cause bad

electrical connections and damaged components.

Position the large RCM electrical connector into the RCM.

-

NOTICE: Do not push the connector to the point where the lever pivots and seats itself. Light pressure is needed to get the connector
into position on the Restraints Control Module (RCM), before using the lever to fully seat the connector. Failure to follow these
instructions may cause component or connector damage.

With the large RCM electrical connector uniformly aligned to the RCM, lightly push in until a subtle audible click is heard and slight resistance is
felt.

4. Connect the large RCM electrical connector.

-

Using the connector position assurance lever, pivot it toward the RCM drawing the connector into the RCM.
-

Make sure the thumb tab is engaged to the retainer on the RCM and locked in place.

5. Connect the small RCM electrical connector.

6. Install the inner floor console support.

7. Install the 4 bolts (2 each side) to the inner floor console support.

-

Tighten to 12 Nm (106 lb-in).

8. Install the screws to the inner floor console support bracket-to-floor instrument panel.

-

Tighten to 12 Nm (106 lb-in).

9. Install the selector lever cable in the selector lever housing.

10. NOTE: When installing the selector lever cable, make sure that the selector lever cable locking tabs are locked in place and the cable end is

Air Bag Control Module|Locations|Page 6279 > < Air Bag Control Module|Locations|Page 6277