Air Door Actuator / Motor: Service and Repair
Temperature Blend Door Actuator - RH, Dual-Zone EATC

TEMPERATURE BLEND DOOR ACTUATOR - RH, DUAL-ZONE EATC

Removal and Installation

NOTE:  It is not required to install the new RH temperature blend door linkage parts included in the RH temperature blend door actuator service part kit
if only the temperature blend door actuator requires replacement and the linkage parts are not broken or binding.

RH temperature blend door actuator and linkage

1. Disconnect the glove compartment damper from the glove compartment.
2. Remove the glove compartment.
3. Remove the RH lower instrument panel insulator.
4. Remove the RH lower floor console trim panel.
5. Remove the 3 RH temperature blend door actuator screws.
6. Disconnect the RH temperature blend door actuator electrical connector.
7. Remove the RH temperature blend door actuator.