Edge FWD V6-3.5L (2007)
Ignition Coil: Service and Repair
IGNITION COIL-ON-PLUG
Exploded View
Removal and Installation
LH side
1. Disconnect the crankcase vent tube quick connect coupling from the valve cover fitting and position aside.
RH side
2. NOTE: The upper intake manifold must be removed to access the RH ignition coil-on-plugs.
Remove the upper intake manifold.
Both sides
3. Disconnect the 6 ignition coil-on-plug electrical connectors.
4. NOTE: When removing the ignition coil-on-plugs, a slight twisting motion will break the seal and ease removal.
Remove the 6 bolts and the 6 ignition coil-on-plugs.
-
To install, tighten to 7 Nm (62 lb-in).
5. To install, reverse the removal procedure.