Edge FWD V6-3.7L (2011)
Control Module HVAC: All Technical Service Bulletins
Instruments, A/C - Outside Temp Inaccurate/Slow Response
TSB 10-23-2
12/03/10
OUTSIDE AIR TEMP READING INACCURATE AND/OR
SLOW TO UPDATE IN WARM AMBIENT
TEMPERATURES
FORD:
2011 Edge
LINCOLN:
2011 MKX
ISSUE
Some 2011 Edge and MKX vehicles built on or before 9/1/2010, may experience the outside air temperature (OAT) reading inaccurate and/or slow to
update in actual ambient temperatures 70 °F (21 °C) or above. Vehicles equipped with dual automatic temperature control (DATC) System may also
experience a lack of A/C cooling at startup. This typically occurs when the OAT sensor is (10-15 °F or more) lower than the actual ambient temperature
during starting up. This causes reduced air[low because the heating ventilation air conditioning (HVAC) blower speed is not adequate for the climate
conditions.
ACTION
Follow the Service Procedure steps to correct the condition.
SERVICE PROCEDURE
1. Reprogram the HVAC module to the latest calibration using IDS release 69.05 or higher. This new calibration is not included in the VCM 2010.9
DVD. Calibration files may also be obtained at the website.
NOTE
AFTER REFLASH THE OAT DISPLAY WILL NEED A FEW MINUTES, INITIALLY, OF CONSTANT DRIVING TO OBTAIN THE
CURRENT OUTSIDE AIR TEMPERATURE.
WARRANTY STATUS: Eligible Under Provisions Of New Vehicle Limited Warranty Coverage
IMPORTANT: Warranty coverage limits/policies are not altered by a TSB. Warranty coverage limits are determined by the identified causal part.
OPERATION
DESCRIPTION
TIME
102302A
2011 Edge, MKX:
0.3 Hr.
Reprogram The HVAC
Module (Do Not Use With
Any Other Labor
Operations)
DEALER CODING
CONDITION
BASIC PART NO.
CODE
19980
04