6. Remove the remote canister vent hose and the dust separator.

7. Remove the canister vent solenoid.

INSTALLATION

1. To install, reverse the removal procedure.

^

Carry out a leak test.  See: Testing and Inspection/Component Tests/Evaporative Emission System Leak Test

^

Carry out the evaporative emission repair verification drive cycle.  See: Testing and Inspection/Component Tests/Evaporative Emission Repair
Verification Drive Cycle

NOTE:  Lubricate all O-ring seals with MERPOL(R) O-Ring Seal Lubricant meeting Ford specification ESE-M99B144-B or equivalent.