6. Disconnect the fuel pulse damper vacuum hose.

7. Disconnect the fuel injector electrical connectors.

8. Remove the bolts and remove the fuel supply manifold.

9. Inspect the O-ring seals. Discard if damaged

INSTALLATION

1. To install, reverse the removal procedure.

CAUTION:
^

Use O-ring seals made of fuel-resistant material. Use of incorrect O-ring seals may result in fuel leakage.

^

Never use silicone grease. Silicone grease may clog fuel injectors.

NOTE:  Lubricate the O-ring seals with clean Super Premium SAE 5W-30 Motor Oil XO-5W30-QSP or equivalent meeting Ford specification

Technician Safety Information|Page 4378 > < Technician Safety Information|Page 4376