Removal

NOTICE: During engine repair procedures, cleanliness is extremely important. Any foreign material, including any material created while
cleaning gasket surfaces, that enters the oil passages, coolant passages or the oil pan can cause engine failure.

1. Remove the oil level indicator.

2. Remove the ignition coil-on-plugs.

3. Disconnect the crankcase vent hose.

4. Disconnect the Cylinder Head Temperature (CHT) sensor electrical connector.

5. Disconnect the Camshaft Position (CMP) sensor electrical connector.

6. Disconnect the radio capacitor electrical connector.

7. Disconnect the Variable Camshaft Timing (VCT) solenoid electrical connector.

8. Detach all of the wiring harness retainers from the valve cover studs and position the harness aside.

9. Remove the 14 valve cover retainers, the valve cover and gasket.

Installation

1. NOTICE: Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These tools

cause scratches and gouges which make leak paths.

Clean and inspect the sealing surfaces.

2. NOTE: The valve cover must be secured within 4 minutes of silicone gasket application. If the valve cover is not secured within 4 minutes, the

sealant must be removed and the sealing area cleaned with metal surface prep.

Apply silicone gasket and sealant to the locations shown.

Valve Cover|Service and Repair|Page 1709 > < Valve Cover|Service and Repair