ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refueling Vapor Recovery System > < Leak Detection Valve, Evaporative System|Diagrams|Page 3760
Page 2
background image

6. Remove the remote canister vent hose and the dust separator.

7. Remove the canister vent solenoid.

INSTALLATION

1. To install, reverse the removal procedure.

^

Carry out a leak test.  See: Testing and Inspection/Component Tests and General Diagnostics/Component Tests/Evaporative Emission System
Leak Test

^

Carry out the evaporative emission repair verification drive cycle.  See: Testing and Inspection/Component Tests and General
Diagnostics/Component Tests/Evaporative Emission Repair Verification Drive Cycle

NOTE:  Lubricate all O-ring seals with MERPOL(R) O-Ring Seal Lubricant meeting Ford specification ESE-M99B144-B or equivalent.

Refueling Vapor Recovery System > < Leak Detection Valve, Evaporative System|Diagrams|Page 3760