Escort ZX2 L4-2.0L DOHC VIN 3 (2000)
PCV Valve Hose: Service and Repair
Crankcase Ventilation Tube
REMOVAL
1. Raise the vehicle; refer to Maintenance/Service and Repair.
2. Drain the engine cooling system; refer to Cooling System.
3. Lower the vehicle.
4. Disconnect the crankcase ventilation tube from the Positive Crankcase Ventilation (PCV) valve.
5. Disconnect the water temperature sensor connector.
6. Disconnect the camshaft position sensor connector.
7. Disconnect the coil pack connector.