Vacuum Solenoid Valve HVAC: Service and Repair

AUTOMATIC TEMPERATURE CONTROL SOLENOID AND MANIFOLD

REMOVAL

1. Remove the audio unit.

2. Disconnect the automatic temperature control (ATC) solenoid and manifold.

1

Disconnect the vacuum connector.

2

Disconnect the electrical connector.

3. Remove the screw and remove the ATC solenoid and manifold.

INSTALLATION

1. To install, reverse the removal procedure.