ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

1-2 Accumulator|Page 4670 > < A/T - E4OD/4R100 Ticking Noise On Start Up|Page 4667
Page 1
background image

Accumulator: Service and Repair
1-2 Accumulator

Special Tools

REMOVAL 

1. Use (A) Servo Piston Remover Replacer to compress the 1-2 accumulator cover and remove the (B) accumulator piston retaining ring.

2. NOTE:  Note the location of the 1-2 accumulator springs for reference during assembly.

1

Remove the l-2 accumulator cover.

2

Remove the lower 1-2 accumulator spring.

3

Remove the accumulator piston.

4

Remove the upper 1-2 accumulator spring.

INSTALLATION 

1. Install the 1-2 accumulator. 

1-2 Accumulator|Page 4670 > < A/T - E4OD/4R100 Ticking Noise On Start Up|Page 4667