ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Auxiliary Evaporator Outlet and Inlet Line|Page 5919 > < Auxiliary Evaporator Outlet and Inlet Line|Page 5917
Page 1
background image

Hose/Line HVAC: Service and Repair
Thermostatic Expansion Valve Manifold and Tube Assembly

Thermostatic Expansion Valve Manifold and Tube Assembly

Removal and Installation

1. Recover the refrigerant.

2. Remove the RH headlamp assembly.

3. Remove the condenser outlet fitting nut and disconnect the fitting.

-

Discard the O-ring seal and gasket seal.

-

To install, tighten to 15 Nm (133 lb-in).

4. Disconnect the 3 PCM electrical connectors.

Auxiliary Evaporator Outlet and Inlet Line|Page 5919 > < Auxiliary Evaporator Outlet and Inlet Line|Page 5917