ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 8772 > < Initial Inspection and Diagnostic Overview|Page 8770
Page 6
background image

-

Is the resistance greater than 10,000 ohms?

Yes

GO to Q7.

No

REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
Q4 CHECK THE SJB REAR PARKING LAMPS OUTPUT CIRCUIT FOR A SHORT TO VOLTAGE

-

Ignition OFF.

-

Disconnect: SJB C2280d.

-

Ignition ON.

-

Do the rear parking lamps continue to illuminate?

Yes

If not equipped with remote start, REPAIR circuit CLS30 (VT/WH) for a short to voltage. TEST the system for normal operation.

If equipped with remote start, GO to Q5.

No

GO to Q6.

-------------------------------------------------
Q5 ISOLATE THE REMOTE START SYSTEM

-

Disconnect: Remote Start C2390.

-

Do the rear lamps continue to illuminate?

Yes

REPAIR circuit CLS30 (VT/WH) for a short to voltage. TEST the system for normal operation.

No

INSTALL a new remote start. TEST the system for normal operation.

-------------------------------------------------
Q6 CHECK THE SJB FRONT PARKING LAMPS OUTPUT CIRCUIT FOR A SHORT TO VOLTAGE

-

Ignition OFF.

-

Disconnect: SJB C2280e.

-

Ignition ON.

-

Do the front parking lamps continue to illuminate?

Yes

REPAIR circuit CLS30 (VT/WH) for a short to voltage. TEST the system for normal operation.

No

GO to Q6.

Initial Inspection and Diagnostic Overview|Page 8772 > < Initial Inspection and Diagnostic Overview|Page 8770