ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Power Distribution Relay > < Power Distribution Module|Service and Repair
Page 2
background image

1. Position the SJB and install the 2 bolts.

-

Tighten the bolts to 2 Nm (18 lb-in).

2. Connect the 7 electrical connectors.

3. Install the RH cowl panel side trim.

4. Install the glove compartment.

5. NOTE: If the SJB is not being replaced, this is the last step that is necessary. Connect the battery.

6. NOTE: When successful, this step provides the calibration necessary for the SJB operation and clears the DTCs B106D and B2477. The clearing

of these DTCs indicates the calibration data has been successfully downloaded to the SJB.

NOTE: DTC B2276 may be set, indicating there are less than 2 transmitters programmed to the SJB.

Download the SJB configuration information from the scan tool to the SJB.

7. NOTE: When successful, this step clears DTCs B2868, B2869, B2870 and B2871. The clearing of these DTCs indicates the SJB has recognized

the tire pressure sensors during the training procedure.

Train the tire pressure sensors.

8. NOTE: DTC C2780 will not clear if any of the pre-set DTCs are still present in the SJB.

Carry out the SJB self-test (must include an on-demand self-test) and then repeat the self-test to confirm all DTCs have been cleared.

9. Rotate the instrument panel dimmer switch from the full dim position to the dome ON position. This will make sure that all displays are visible

under all lighting conditions.