VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

GO to V6.

No

GO to V33.

-------------------------------------------------
V6 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO VOLTAGE

-

Connect the negative battery cable.

-

Ignition ON.

-

Measure the voltage between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit VDB07
(VT/OG), harness side and ground.

-

Is the voltage greater than 6 volts?

Yes

REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

VERIFY all module fuses are OK. If OK, REPEAT the network test with the scan tool.

-------------------------------------------------
V7 CHECK THE MS-CAN CIRCUITS BETWEEN THE SJB AND THE DLC FOR AN OPEN

-

Disconnect: SJB C2280b.

-

Measure the resistance between the SJB C2280b-37, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06 (GY/OG),
harness side.

-

Measure the resistance between the SJB C2280b-38, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG),
harness side.