Accumulator HVAC: Description and Operation

NOTE:  Replacement of the suction accumulator/drier is necessary any time a major component of the refrigerant system is replaced.

Major components include:

-

A/C condenser core

-

A/C compressor

-

A/C evaporator core

-

a refrigerant hose/line

An A/C evaporator core orifice or O-ring seal is not considered a major component but the A/C evaporator core orifice should be replaced whenever the
A/C compressor is replaced for lack of performance.

In addition to the preceding condition, the suction accumulator/drier should also be replaced if one of the following conditions exist:

-

The suction accumulator/drier is perforated.

-

The refrigerant system has been opened to the atmosphere for a period of time longer than required to make a minor repair.

-

There is evidence of moisture in the system such as internal corrosion of metal refrigerant lines or the refrigerant oil is thick and dark.