Any probe entering the terminal may enlarge the contact spring opening creating an intermittent signal. Insert the correct mating terminal (Location A)
from the service kit and feel for a loose fit.
Electrical short inside the harness
1
= Solder coated wire to ground
2
= Harness protective tape
3
= Intermittent short
Solder coated wire pierced through the insulation of another circuit
4
= Grounding foil
Electrical short within the harness
Splice tape removed
1
= Intermittent short
Splice covered
2
= Wire strand
3