Removal and Installation

1. Remove the bolts and position the accelerator pedal aside.

-

To install, tighten to 25 Nm (18 lb-ft).

2. Disconnect the floor/defrost door vacuum control motor vacuum connector.
3. Remove the 2 floor/defrost door vacuum control motor screws.
4. Rotate the floor/defrost door vacuum control motor until it clears the retaining arm and remove.
5. To install, reverse the removal procedure.

Panel Door

VACUUM CONTROL MOTOR - PANEL DOOR

Removal and Installation

1. Remove the instrument panel. Refer to:  Body and Frame, Interior Moulding/Trim, Dashboard/Instrument Panel, Service and Repair, Instrument

Panel, See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel

2. Disconnect the panel door vacuum control motor vacuum connector.
3. Remove the 2 panel door vacuum control motor screws.
4. Rotate the panel door vacuum control motor until it clears the retaining arm and remove.
5. To install, reverse the removal procedure.