Bimetal Sensor

^ Check the bimetal sensor.

^ Bring the temperature of the bimetal sensor below 24°C (75°F) and apply 54 kPa (16 in Hg) vacuum.

Does the door close (go to the hot air position)? 

YES --  Go to AIS 7. See: AIS 7 Air Filter Check 

NO  --  Replace bimetal sensor.

AIS 7 Air Filter Check

^ Check the air filter.

Is the air filter excessively dirty? 

YES --  Replace air filter.

NO  --  Go to AIS 8. See: AIS 8 Sealing Integrity

AIS 8 Sealing Integrity

^ Check hoses that connect air cleaner to engine.

Are there cracks or leaks? 

Are there any cracks in the air cleaner assembly?  

^ Check the air filter for proper sealing.

Are there any leaks around the air filter seal? 

YES --  Replace parts as required.

NO  --  Go to AIS 9. See: AIS 9 Check Torque

AIS 9 Check Torque

^ Check clamps and air cleaner screws (if equipped) for proper torque.

Is torque correct? 

YES --  Go to AIS 10. See: AIS 10 Check Idle Speed 

NO  --  Tighten to specification.

AIS 10 Check Idle Speed

^ Check idle speed to specifications.