Explorer 2WD V6-245 4.0L SOHC VIN K SFI (2001)
Service Port HVAC: Description and Operation
The high-pressure service gauge port valve is located on the front A/C manifold and tube.
The low pressure service gauge port valve is located on the suction accumulator/drier.
The fitting is an integral part of the refrigeration line or component.
-
Special couplings are required for both the high-side and low-side service gauge ports.
-
A new Schrader-type valve core can be installed if the seal leaks.
-
Always install the A/C charging valve cap on the service gauge port valve after repairing the refrigerant system.