ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Evaporative System Service Port > < Evaporative Emission Control Canister|Description and Operation|Page 4585
Page 2
background image

6. Remove the canister vent solenoid and the evaporative emission tube.

1

Disconnect the canister vent solenoid hose from the canister vent solenoid.

2

Remove the canister vent solenoid.

3

Remove the evaporative emission canister purge sleeve.

4

Remove the evaporative emission tube.

7. Remove the evaporative emission canister from the evaporative emission canister bracket.

INSTALLATION

1. To install, reverse removal procedure.

^

Leak test the evaporative emissions system. For additional information, refer to Evaporative Emission System Leak Test.  See: Testing and
Inspection/Component Tests and General Diagnostics/Component Tests/Evaporative Emission System Leak Test

^

Carry out the evaporative emission repair verification drive cycle. For additional information, refer to Evaporative Emission Repair
Verification Drive Cycle.  See: Service and Repair

NOTE:  Lubricate all O-ring seals with MERPOL(R) O-ring Seal Lubricant or equivalent meeting Ford specification ESE-M99B144-B.

Evaporative System Service Port > < Evaporative Emission Control Canister|Description and Operation|Page 4585