Expansion Block/Orifice Tube: Description and Operation

NOTE:  A new A/C evaporator core orifice should be installed whenever a new A/C compressor is installed.

A/C Evaporator Core Orifice

The A/C evaporator core orifice has the following characteristics:

^

It is color-coded red.

^

It has an orifice diameter of 1.6 mm (0.062 inch).

^

It is located in the A/C evaporator core inlet tube.

^

It has filter screens located on the inlet and outlet ends of the tube body.

^

The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the A/C evaporator core orifice.

^

O-rings on the A/C evaporator core orifice prevent the high-pressure liquid refrigerant from bypassing the A/C evaporator core orifice.

^

Adjustment or service cannot be made to the A/C evaporator core orifice assembly. A new evaporator core orifice assembly must be installed.