Page 11
background image

2. Remove and discard the in-line transmission fluid filter, if equipped.
3. To aid in attaching the cleaner to the transmission steel cooler lines, connect 2 additional rubber hoses to the transmission end of the steel

transmission cooler lines as described.
^

Connect the cleaner tank pressure line to the steel transmission cooler return line (longest line).

^

Connect a tank return hose to the steel transmission cooler pressure line (shorter line). Place the outlet end of this hose in the solvent tank
reservoir.

4. Turn on the pump and allow the transmission fluid to circulate a minimum of 5 minutes (cycling switch on and off will help dislodge contaminants

in the cooler system).

5. Switch off the pump and disconnect the pressure hose from the transmission cooler return line.
6. Use compressed air to blow out the cooler(s) and lines (blow air into the transmission cooler return line) until all the fluid is removed.
7. Remove the rubber return hose from the remaining steel cooler line.