17. NOTICE: To prevent selector lever cable damage, do not apply force to the selector lever cable between the manual control lever and the

selector lever cable bracket.

NOTE: When installing the selector lever cable end, make sure that the selector lever cable end is correctly installed onto the manual control lever
ball stud. Pull back on the selector lever cable end to make sure that the selector lever cable end is correctly installed onto the manual control lever
ball stud.

With the manual lever in NEUTRAL, connect the selector lever cable onto the manual control lever ball stud and move the locking tab down.

1. Selector lever cable end.

2. Locking tab.

-

Listen for the audible click.

-

Pull back on the selector lever cable to make sure that it is correctly installed.

18. Install the selector lever cable heat shield.

19. Using the refill procedure, fill and check the transmission fluid. For additional information, refer to Transmission Fluid Drain and Refill  See:

Service and Repair/Procedures/6R80/Transmission Fluid Drain and Refill.