Accumulator HVAC: Service and Repair

REMOVAL

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
system contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Remove the air cleaner housing.

3. Disconnect the refrigerant lines from the suction accumulator.

1

Remove the nuts.

2

Disconnect the refrigerant lines. 
-

Discard the O-ring seals.

4. Remove the bolt.
5. Remove the radiator grille.

6. Remove the three pin type retainers.

Accumulator HVAC|Description and Operation|Page 11296 > < Accumulator HVAC|Description and Operation