ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Auxiliary Climate Control|Page 2917 > < Auxiliary Climate Control|Page 2915
Page 5
background image

3. Remove the bolts and position aside the degas bottle.

4. Remove the nut and the refrigerant line bracket.

5. Disconnect the condenser to evaporator line spring-lock coupling from the evaporator inlet.

6. Disconnect the auxiliary refrigerant line spring-lock coupling.

-

Discard the O-ring seals.

7. Remove the bolt from the evaporator outlet line bracket near the degas bottle.

Auxiliary Climate Control|Page 2917 > < Auxiliary Climate Control|Page 2915