Pressure Feedback Exhaust Sensor: Service and Repair

DIFFERENTIAL PRESSURE FEEDBACK EXHAUST GAS RECIRCULATION (EGR) SYSTEM

Removal and Installation

1. Disconnect the battery ground cable.

2. Remove the engine appearance cover.

3. Disconnect the electrical connector.

4. Remove the differential pressure feedback EGR sensor.
5. To install, reverse the removal procedure.