ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Description and Operation
Page 1
background image

Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

REMOVAL

NOTE:

-

Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

-

New O-ring seals, lubricated in clean PAG oil, must be installed before reconnecting any A/C fitting which has been disconnected.

1. Recover the refrigerant.
2. Remove the air cleaner.
3. Remove the radiator grille.

4. Remove the components in the order indicated in the illustration and table.

INSTALLATION

1. To install, reverse the removal procedure.
2. Lubricate the refrigerant system with the correct amount of clean PAG oil.
3. Evacuate, leak test and charge the refrigerant system.

Air Door, HVAC > < Accumulator HVAC|Description and Operation