ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2789 > < Initial Inspection and Diagnostic Overview|Page 2787
Page 23
background image

-

Is the concern still present?

Yes

INSTALL a new HVAC module. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------

Pinpoint Test J: The Audio Control Module (ACM) Does Not Respond To The Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test J: The Audio Control Module (ACM) Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14, Module Communications Network for schematic and connector information.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 130, Audio System/Navigation for schematic and connector information.  See: Diagrams/Electrical Diagrams/Diagrams By
Number

Normal Operation

Circuits VDB06 (GY/OG) (MS-CAN +) and VDB07 (VT/OG) (MS-CAN -) provide the network connection to the Audio Control Module (ACM).
Voltage for the ACM is provided by circuits CBP12 (GN/WH) and SBP03 (BU/RD). Circuit GD114 (BK/BU) provides ground.

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

ACM

PINPOINT TEST J: THE ACM DOES NOT RESPOND TO THE SCAN TOOL

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE: Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.

-------------------------------------------------
J1 CHECK THE ACM VOLTAGE SUPPLY CIRCUITS FOR AN OPEN

-

Ignition OFF.

-

Disconnect: ACM C290a.

-

Ignition ON.

-

Measure the voltage between the ACM C290a-1, circuit SBP03 (BU/RD), harness side and ground; and between the ACM C290a-2, circuit
CBP12 (GN/WH), harness side and ground.

-

Are the voltages greater than 10 volts?

Yes

Initial Inspection and Diagnostic Overview|Page 2789 > < Initial Inspection and Diagnostic Overview|Page 2787