ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Suction Accumulator|Page 7176 > < Accumulator HVAC|Description and Operation
Page 1
background image

Accumulator HVAC: Service and Repair
Suction Accumulator

SUCTION ACCUMULATOR

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

All vehicles

1. Recover the refrigerant.
2. Remove the PCM.
3. Remove the low-side service port stem bracket bolt.

-

To install, tighten to 11 Nm (8 lb-ft).

4. Disconnect the A/C cycling switch electrical connector.
5. Remove the suction accumulator bolt.

-

To install, tighten to 11 Nm (8 lb-ft).

Suction Accumulator|Page 7176 > < Accumulator HVAC|Description and Operation