ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Seat Occupant Classification Module - Air Bag > < Air Bag Control Module|Locations|Page 499
Page 3
background image

4. Connect the large RCM electrical connector.

-

Using the connector position assurance lever, pivot it toward the RCM, drawing the connector into the RCM.
-

Make sure the thumb tab is engaged to the retainer on the RCM and locked in place.

5. Connect the small RCM electrical connector and push the lock tab in.

6. If equipped, install the floor console.

7. If equipped, install the front center seat cushion and cupholder assembly.

8. Repower the SRS. For additional information, refer to Supplemental Restraint System (SRS) Depowering and Repowering  See: Body and

Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Air Bag(s) Arming and Disarming/Service and Repair.

9. If a new RCM was installed, carry out the appropriate steps to complete the Programmable Module Installation (PMI) procedure.   See: Powertrain

Management/Computers and Control Systems/Information Bus/Testing and Inspection/Programming and Relearning

Seat Occupant Classification Module - Air Bag > < Air Bag Control Module|Locations|Page 499