F1-F3

Normal Operation

The instrument cluster communicates with the diagnostic tool through the controller area network (CAN) circuits 1827 (WH/LG) and 1828 (PK/LG).

Check the CAN circuits between the instrument cluster C220a and the data link connector (DLC) C251. The total resistance values must not be more
than 5 ohms. If the resistance is more than 5 ohms there is an open in circuit 1827 (WH/LG) and 1828 (PK/LG), damage to the DLC C251, damage to
the instrument cluster C220a, or a problem with the in-line connector.

Possible Causes