ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Accumulator HVAC|Service Precautions|Page 7999 > < Accumulator HVAC|Service Precautions|Page 7997
Page 1
background image

Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

REMOVAL

CAUTION:  Refrigerant Compressor Oil (Mineral Oil) F73Z-19577-AA (Motorcraft YN-9-A) should be used to lubricate R-134a refrigerant
system O-ring seals only and should not be added to R-134a refrigerant systems as an A/C compressor lubricant. PAG Refrigerant Compressor
Oil F7AZ-19D589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B only should be used as an A/C
compressor lubricant.

NOTE:

-

Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

-

New O-ring seals, lubricated in clean mineral oil, must be installed before reconnecting any A/C fitting which has been disconnected.

1. Recover the refrigerant.
2. Remove the powertrain control module (PCM).
3. Remove the battery and battery tray.

4. Remove the parts in the order indicated in the illustration and table.

INSTALLATION

Accumulator HVAC|Service Precautions|Page 7999 > < Accumulator HVAC|Service Precautions|Page 7997