F 150 2WD Pickup V8-5.4L SOHC VIN L (1997)
Air Door Actuator / Motor: Customer Interest
A/C - No Airflow From Floor Vents
Article No.
97-19-19
09/15/97
^
AIR CONDITIONING - NO AIRFLOW FROM FLOOR
HEATER - NO AIRFLOW FROM FLOOR
LIGHT TRUCK:
1997 EXPEDITION, F-150-350 SERIES
ISSUE:
Airflow from the air conditioner or heater will not switch to FLOOR mode on some vehicles. This may be due to the panel/floor door vacuum motor
linkage being disconnected from the door pivot.
ACTION:
Replace the vacuum motor assembly. Refer to the following Service Procedure for details.
SERVICE PROCEDURE
1.
Verify concern.
2.
Remove and replace panel/floor door Vacuum Motor (F75Z-18A318-AA). Refer to the appropriate Service Manual for removal procedure. Make
sure linkage is fully engaged in door pivot.
3.
Verify proper heating system operation.
PART NUMBER
PART NAME
F75Z-18A318-AA
Vacuum Motor Assembly
OTHER APPLICABLE ARTICLES: NONE
WARRANTY STATUS: Eligible Under The Provisions Of Bumper To Bumper Warranty Coverage
OPERATION
DESCRIPTION
TIME
971919A
Replace Vacuum Motor
0.6 Hr.
Assembly
DEALER CODING
CONDITION
BASIC PART NO.
CODE
18A318
X2
OASIS CODES: 208000, 208300, 208999