Expansion Block/Orifice Tube: Service and Repair

Thermostatic Expansion Valve

Removal and Installation

1. Recover the refrigerant. 

2. Remove the Thermostatic Expansion Valve (TXV) manifold and tube bracket bolt.

-

To install, tighten to 8 Nm (71 lb-in).

3. Remove the TXV fitting nut and disconnect the fitting.

-

Discard the gasket seals.

-

To install, tighten to 15 Nm (133 lb-in).

4. Remove the 2 TXV bolts.

-

To install, tighten to 8 Nm (71 lb-in).

5. Remove the TXV.

-

Discard the gasket seals.

6. To install, reverse the removal procedure.

-

Install new gasket seals.