Windshield: Vehicle Damage Warnings

CAUTION:

^

Care must be taken to avoid scratching the pinch weld.

^

After replacing the urethane installed glass, the vehicle should not be driven until the urethane has cured. The curing times at temperatures above 
13°C (55°F) and relative humidity above 50% is 12-24 hours (refer to Essex Drive Away Chart for cure times, as temperatures and humidity
vary). Inadequate curing of the urethane may adversely affect the strength of the urethane adhesive bond.

^

Wipe off the Urethane Glass Prep immediately after each application because it flash dries.

^

If a vehicle is to be driven within 24 hours of urethane adhesive application, Urethane Adhesive Essex U-216 meeting Ford specification
WSB-M2C316-B must be used due to its one hour cure time.

^

Open the windows to prevent the windshield glass from being pushed out by air pressure if a door is closed.