F 150 Heritage 2WD Pickup V8-4.6L SOHC VIN W (2004)
Use Rotunda special service tool kit 303-1398 to remove porcelain broken inside the ground electrode shield. (FIGURE 10)
Porcelain Removal - Preparation
CAUTION
THE ENGINE AND THE BONDING ADHESIVE MUST BE ROOM TEMPERATURE OF 70 °F (21 °C) OR HIGHER FOR PROPER CURE
AND BOND STRENGTH. VERIFY EXPIRATION DATE OF ADHESIVE.
CAUTION
DO NOT REUSE PINS. THIS ENSURES THE CORRECT SURFACE CHARACTERISTICS FOR BONDING.
1.
Remove any remaining electrode material from broken porcelain with long nose reach pliers.
2.
Spray Motorcraft® Metal Brake Parts Cleaner into the porcelain hole for 2-4 seconds using the straw nozzle supplied with the brake cleaner can.