ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

4R100 Automatic Transmission|Page 5321 > < 4R100 Automatic Transmission|Page 5319
Page 12
background image

4

NOTE:  Use a crescent wrench on the manual control lever or the outer flats of the manual control lever shaft assembly when installing the
inner manual valve detent lever nut.

Install the inner manual valve detent lever nut.

3. CAUTION:  Do not reuse the old filter and seal assembly.

CAUTION:  Make sure that the pump bore is clean and the old filter seal has been removed.

NOTE:  Prior to installation, lightly lubricate the fluid filter seal with clean automatic transmission fluid.

Install a new filter and seal assembly by pressing it into place.

4. NOTE:  Do not discard the gasket unless damaged. This is a reusable gasket.

NOTE:  Apply a light coat of petroleum jelly to hold the gasket to the fluid pan.

Position the gasket onto the clean fluid pan. Make sure the magnet is positioned over the dimple in the fluid pan.

5. CAUTION:  Mixing the 4x2-style and 4x4-style transmission fluid filters and transmission pan assembly components can cause transmission

damage.

Install the correct pan with gasket for this application. Alternately tighten the bolts.

4R100 Automatic Transmission|Page 5321 > < 4R100 Automatic Transmission|Page 5319