ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Harmonic Balancer|Page 2060 > < Harmonic Balancer|Page 2058
Page 2
background image

1. NOTE:  If not secured within four minutes, sealant must be removed and the sealing area cleaned with Metal Surface Cleaner F4AZ-19A536-RA

or equivalent meeting Ford specification WSE-M513392-A. Allow to dry until there is no sign of wetness, or four minutes, whichever is longer.
Failure to follow this procedure can cause future oil leakage.

Apply silicone to the woodruff key slot on the crankshaft pulley.
-

Use Silicone Gasket and Sealant F6AZ-19562-AA or equivalent meeting Ford specification WSE-M4G323-A6.

2. Use the Crankshaft Damper Replacer to install the crankshaft pulley.

3. Install the bolt and washer. Tighten the bolt in four stages.

-

Stage 1: Tighten to 90 Nm (66.15 ft. lbs.). 

-

Stage 2: Loosen the bolt.

-

Stage 3: Tighten to 47-53 Nm (34-39 ft. lbs.)

-

Stage 4: Tighten an additional 85-90°. 

4. Install the drive belt. 
5. Install the engine cooling fan and the fan shroud. 

Harmonic Balancer|Page 2060 > < Harmonic Balancer|Page 2058